AC Inverter Drive
Varispeed-F7 Variable Speed Drives We deal in Varispeed-F7 Variable Speed Drives:
- Powerful, Compact, Energy-Saving, Current Vector Control Inverter
- Wide voltage range : 320 to 530 VAC
- Four-in-line control
- Open loop control
- V/f with PG
- Standard V/f
- Flux Vector
- 1:100 speed control range
- Static/dynamic auto-tuning on any motor
- High slip braking function
- Copy function for faster parameter loading
- Complete motor protection
- Built in PID loop with sleep function to save more energy
- Braking chopper in-built up to 18kW
L&T A 1000 Drives with its latest vector control technology is capable of delivering higher order performance to meet customer expectations. A 1000, not only performs but is aesthetically superior and incredibly powerful. A truly reliable product to address future requirements & current needs, only possible from L&T Features Motor Drive Performance leading the pack
- Uses most advanced drive technology to run induction and synchronous motors
- Positioning accuracy without use of external sensors
- Excellent torque characteristics
- Loaded with new auto- tuning features
- Tackles power loss
User Friendly Installation & Delivers Longer Life
- Easy setup with application presets
- Open to all serial network protocols
- Easy to maintain
The drive for a greener world
- Saves energy
- Environment friendly
Easy Setup Immediately setup with Application Presets A1000 automatically sets parameters needed for all major applications. Simply selecting the appropriate application instantly optimizes the drive for top performance, saving enormous time, setting up for a trial run Example using application presets Selecting "Conveyor" optimizes five parameter settings so that drive is ready to start running your conveyor application immediately. Long Life Performance A 1000 with 10 years of durable performance Motor Life With relatively low copper loss in the rotor and a cool shaft during operation, synchronous motors have a bearing life twice that of induction motors. Performance Life Monitors Equipped with performance life monitors that notify the user of part wear and maintenance periods to prevent problems before they occur. Drive outputs a signal to the control device indicating components that may need replacement. Specifications
|
Standard Specifications
|
Model CIMR-AD4A
|
2
|
4
|
5
|
7
|
11
|
18
|
23
|
31
|
38
|
44
|
58
|
72
|
88
|
103
|
139
|
165
|
208
|
250
|
296
|
362
|
414
|
515
|
675
|
|
Typical Motor
|
Normal Duty
|
0.75
|
1.5
|
2.2
|
3
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
110
|
132
|
160
|
185
|
220
|
250
|
355
|
|
Capacity
|
Heavy Duty
|
0.4
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
110
|
132
|
160
|
185
|
220
|
315
|
|
Rated Output
|
Normal Duty
|
1.6
|
3.1
|
4.1
|
5.3
|
8.5
|
13.3
|
17.5
|
24
|
29
|
34
|
44
|
55
|
67
|
78
|
106
|
126
|
159
|
191
|
226
|
276
|
316
|
392
|
514
|
|
Capacity in KVA
|
Heavy Duty
|
1.4
|
2.6
|
3.7
|
4.2
|
7
|
11.3
|
13.7
|
18.3
|
24
|
30
|
34
|
46
|
57
|
69
|
85
|
114
|
137
|
165
|
198
|
232
|
282
|
343
|
461
|
|
Rated Output
|
Normal Duty
|
2.4
|
4.1
|
5.4
|
6.9
|
11.1
|
17.5
|
23
|
31
|
38
|
44
|
58
|
72
|
88
|
103
|
139
|
165
|
208
|
250
|
296
|
362
|
414
|
515
|
675
|
|
Current A
|
Heavy Duty
|
1.8
|
3.4
|
4.8
|
5.5
|
9.2
|
14.8
|
18
|
24
|
31
|
39
|
45
|
60
|
75
|
91
|
112
|
150
|
180
|
216
|
260
|
304
|
370
|
450
|
605
|
|
Enclosure Type
|
NEMA-1 (Can be used as IP00 by removing top & bottom covers)
|
IP00
|
|
Overload Tolerance
|
Normal Duty Rating:120% of rated output current for 60s
|
Heavy Duty Rating: 150% of rated output current for 60 s
|
|
Max. Output Voltage
|
Proportional to input voltage
|
|
Max. Output Frequency
|
400 Hz
|
|
Rated Voltage/Rated Frequency
|
Three-Phase 380 to 480 VAC, 50/60 Hz
|
|
Allowable Voltage Fluctuation
|
-15% to +10%
|
|
Allowable Frequency Fluctuation
|
+5%
|
|
Harmonic Suppression
|
DC Reactor
|
Option
|
Built-in
|
|
Braking Function
|
Braking Chopper
|
Built-in
|
Option
|
|
Control Characteristics
|
Control Method
|
V/f Control, with PG, Open Loop Vector Control, Closed Loop Vector Control with PG, Open Loop Vector Control For PM, Advanced Open Loop Vector Control for PM , Closed Loop Control for PM.
|
|
Frequency Control Range
|
0.01 to 400 Hz
|
|
Frequency Setting Resolution
|
Digital reference: 0.01 Hz
Analog reference: 0.03 Hz/60 Hz (11 bit)
|
|
Output Frequency Resolution
|
0.001 Hz
|
|
Frequency Setting Signal
|
-10 to +10 V, 0 to +10 V, 4 to 20mA, pulse train
|
|
Starting Torque
|
150%/3 Hz (V/f Control and V/f Control with PG), 200%/0.3 Hz (Open Loop Vector Control), 200%/0 RPM (Closed Loop Vector Control, Closed Loop Vector Control fro PM, and Advanced Open Loop Vector Control for PM), 100%/5% Speed (Open Loop Vector Control for PM
|
|
Speed control Range
|
1:1500 (closed loop vector control and closed loop vector control for PM)
1:200 (Open loop vector control) 1:40)V/f control with PG)
1:20 (Openloop vector control for PM) 1:100 (Advanced Open loop vector control for PM
|
|
Speed Control Accuracy
|
+0.2% n Open Loop Vector Control (25oC+10oC) +0.2% in Closed Loopvector control (25oC+10oC)
|
|
Speed Response
|
10 Hz in Open loop vector control 25oC+10oC), 50 Hz in Closed loop vector control (25oC+10oc) (Excludes temperature fluctuation when performing Rotational Auto Tuning)
|
|
Accel/Decel Time
|
0.00 to 6000.0 s (4 selectable combinatinos of independent acceleration and deceleration settings)
|
|
Braking Torque
|
Drives of 200/400V 30kW or less have a built-in braking transistor
(Over excitation Deceleration, High slip Braking: Approx 40%)
Continuous regen. Torque: approx: 20% 125% with dynamic braking resistor option: 10% ED, 10s, internal braking transistor
|
|
V/f Characteristics
|
User-selected programs and V/f preset patterns possible
|
|
Main Control Functions
|
Torque Control, Droop Control, Speed/Torque Control switch, Feed Forward Control, Zero Servo Control, Momentary, Power Loss Ride-Thru, Speed Search, Over Torque detection, Torque limit, 17 step Speed (Max.), accel/decel, time switch, S-curve accel/decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Online Tunign, Dwell control.
|
|
Protection Functions
|
Motor Protection
|
Motor Overheat protection based on output current
|
|
Over Voltage Protection
|
200 V class: Stops when DC bus exceeds approx. 410 V, 400 V class: Stops when DC bus exceeds approx. 820 V
|
|
Under voltage Protection
|
200 V class: Stops when DC bus exceeds approx. 190 V, 400 V class: Stops when DC bus exceeds approx. 380 V
|
|
Momentary Power Loss Ride-Thru
|
Stops immediately after 15 ms or longer power loss )default). Continuous operation during power up to 2s (standard)
|
|
Stall Prevention
|
Stall prevention during acceleration/deceleration and constant speed operation
|
|
Ground Fault Protection
|
Protection by electronic circuit
|
|
Interface
|
Charge LED
|
Charge LED remains lit until DC bus has fallen below approx. 50 V
|
|
Digital Inputs
|
8 nos. programmable (24 VDC Sink/Source/External supply configurable)
|
|
Digital Outputs
|
4 nos. (1Fixed/3 programmable )2 nos. open collector-48
VDC & 2nos. Relay- 230VAC/30VDC
|
|
Analog Inputs
|
3 nos. programmable - 2 nos. 0 to + 10 VDC & 1 no./0/4 to 20mA
|
|
Analog Outputs
|
2 nos. Programmable- 10 to +10 VDC
|
|
Pulse Train I/O
|
0 to 32 kHz max. -1 no. input & 1 no. output
|
|
Communication
|
Modbus RS422/RS485 with speed upto 115.2 kbps
|
|
Safety I/O
|
2 nos. hardware base block inputs & 1 no. safety electronic device monitor output (complying to UL508C, EN954-1 Ca 3, IEC/EN61508 SIL2)
|
|
Option
|
I/O
|
Analog Input (AI-A3)-3 AI, Digital Input (DI-A3)-16 DI, Analog Monitor (AO-A3)02AO, digital Output (DO-A3)- 8DO
|
|
Encoder Interface
|
PG-B3 for Complimentary type PG up to 50 KHz, PG-X3 for Line Driver type PG up to 300 Khz
|
|
Communication
|
PROFIBUS-DP (SI-P3), Device Net (SI-N3), CAN open (SI-S3), MECHATROLINK-2 (SI-T3)
|
|
Others
|
LCD Operator, External 24 V supply; Braking Unit
|
|
Environment
|
Area of use
|
Indoors
|
|
Ambietn Temperature
|
-10 to +50oC
|
|
Humidity
|
95% RH or less (no condensation)
|
|
Storage Temperature
|
-20 to 60oC (short-term temperature during transportation)
|
|
Altitude
|
Up to 1000 meters
|
|
Shock
|
10 Hz to 20 Hz, 9.8 m/s2 max. 20 Hz, 5.9 m/s2 (400V:55 Kw-HD or more ) or 2.0 m/s2 max. (400V:75 Kw-HD or less)
|
|
|
Standard compliance
|
RoHS compliant UL 508oC, eN61800-5-1, EN954-1 Cat3, ISO 13849-1 )Cat3, PLD), IEC/EN61508 SIL2
|
Click here for more details.
|