Temperature Controller (Process Controllers)
Compact size program controller with high functionality and high performance
Features
Program Controller Specifications
A liquid crystal display program controller with maximum of 15 patterns and 99 steps.
Full Multiple Inputs
The multiple inputs of Thermocouple (13 types)
- RTD (2 types)
- Voltage (5 types)
- Current (1 type) input
Utilizes a liquid crystal display
- The indication range has been extended to 5 digits
- Realized the various indication with 7 segments
- Adopted LED for the back light
Backup and Initialization for the Setting Value.
Compact Size
A compact sized body with depth of only 65mm. In addition, the protrusion of the front panel is only 2mm when TTM-339 is mounted.
Loader communication function
It is best for the set up work of a complicated parameter peculiar to the program controller.
- Cable: Option (sold separately)
- Software: Option (free) It can be downloaded from our website (Under development)
Blind function
The system can be configured so that only the selected parameters are displayed from the set of parameters.
Manual control
A manual output function enables application of various instrumentation systems.
Communication function (RS485: TOHO exclusive protocol / MODBUS)
The cable can be extended up to the length of 500m, and can connect up to 31 units simultaneously. With one host computer, a centralized control such as "The collection of all data" and "Change of respective setting value" are possible from a distance place Standard Specifications Function
|
Program specifications
|
Output in operation/End signal output selectable and configurable
|
|
External drive signal selection
|
Internal operation, external operation
|
|
Temperature range setting for
power failure recovery
|
Temperature input
|
0.0 to 2999.9, 0 to 2999(oC)
|
|
Analog input
|
0 to 2999 (digit)
|
|
Timer specifications
|
Setting unit
|
1 min
|
|
Setting time
|
0 to 99 hrs 59 min
|
|
Setting accuracy
|
+(0.5% +0.5 sec) of setting time
|
|
Manipulated variable
|
Manipulated variable function selection (MLF) |
None, Manipulated variable limiter, manipulated variable current limiter
|
|
Manipulated variable limiter
|
Upper limit
|
MLL1 to 100.0 (%), MLL2 to 100.0(%)
|
|
(MLH1 to MLH4)
|
MLL3 to 100.0(%), MLL4 to 100.0(%)
|
|
Lower limit
|
0.0 to MLL1(%), 0.0 to MLL2(%)
|
|
(MLL1 to MLL4)
|
0.0 to MLL3(%), 0.0 to MLL4(%)
|
|
Manipulated variable change
|
Percentage of rise for manipulated variable
|
0.0 to 549.9(%)(0.0% : function OFF)
|
|
limiter rise
|
Rise time of manipulated variable
|
0 to 3600 (sec) (0: function is none)
|
|
Setting limiter (SLL), (SLH)
|
Upper limit (SLH)
|
Temperature input
|
(SLL+5.0) to SV setting range upper limit, (SLL+5) to SV setting range upper limit (oC ) |
|
Analog input
|
(SLL+50) to SV setting range upper limit (digit)
|
|
Lower limit (SLL)
|
Temperature input
|
SV setting range lower limit to (SLH-5.0), SV setting range lower limit to (SLH-5)(oC ) |
|
Analog input
|
SV setting range lower limit to (SLH-50) (digit)
|
|
Scaling setting
|
Upper limit (FSH1)
|
FSL1 to 29999 (digit)
|
|
(Analog input only)
|
Lower limit (FSL1)
|
19999 to FSH1 (digit)
|
|
Control type (CNT)
|
PID control, ON/OFF control
|
|
PV correction gain setting (PVG)
|
0.500 to 2.000 (times)
|
|
PV correction zero setting (PVS)
|
Temperature input
|
999.9 to 999.9, 999 to 999(oC )
|
|
Analog input
|
9999 to 9999 (digit)
|
|
PV filter setting (PDF1)
|
0.0 to 99.9 (sec)
|
|
Special PV filter setting (PDFS)
|
0.0 to 99.9 (sec)
|
|
Anti reset windup
|
0.0 to 110.0 (%) (Function OFF by 110.0% setting)
|
|
Manual reset
|
0.0 to 100.0 (%) (100.0 to 100.0 (%) if there is auxiliary control)
|
|
Main control loop abnormal
|
PV variation setting
|
Temperature input
|
0.0 to 999.9, 0 to 999 (oC )
|
|
Analog input
|
0 to 9999 (digit) (The decimal point position is the specified position.) |
|
Time setting
|
0 to 3600 (sec)
|
|
Decimal point position setting
|
Temperature input
|
1oC , 0.1oC
|
|
(DP)
|
Analog input
|
1/digit, 0.1/digit,0.01/digit, 0.001/digit, 0.0001/digit
|
|
Lock function (LOC)
|
Normal screen, pattern No. setting mode, alarm temperature setting mode, PID setting mode, common parameter setting mode (SET1 to 12), setting temperature (all steps at one time), wait function setting (all steps at one time), time signal 1 to 4 function setting (all steps at one time), manipulated variable limiter function setting (all steps at one time), setting time (all steps at one time), end signal ON time
|
|