Product Code : J1000
Compact V/F Control Drive
Reliability, the world has come to expect from Yaskawa as a global leader is now packed into an even smaller, more powerful unit. Presented by L&T to meet diverse application requirements supplied by indepth technical expertise.
Ratings & Dimensions
Rated Input Voltage Range
Drive Model CIMR-JA
Rated Output Capacity
Dimensions (mm)
Normal Duty
Heavy Duty
W
H
D
KW
Amp
KVA
Kw
200V-240V 1 Phase
BA 0001
0.2
1.2
0.5
0.1
0.8
0.3
8
128
76
BA 0002
0.4
1.9
0.7
1.6
0.6
68
BA 0003
0.75
3.5
1.3
3.0
1.1
118
BA 0006
6
2.3
5.0
108
137.5
BA 0010
2.2
9.6
3.7
1.5
8.0
154
200V-240V 3 Phase
2A 0001
2A 0002
2A 0004
2A 0006
2A 0008
3
6.9
2.6
129
2A 0010
2A 0012
12
4.6
11.0
4.2
2A 0018
17.5
6.7
14.0
5.3
140
143
2A 0020
5.5
19.6
7.5
380V-480V 3 Phase
4A 0001
0.9
81
4A 0002
2.1
1.8
1.4
99
4A 0004
4.1
3.1
3.4
4A 0005
5.4
4.8
4A 0007
4A 0009
8.8
7.2
4A 0011
11.1
8.5
9.2
7.0
Drive Specifications
Item
Specification
Rated Input Voltage
200V Class Single Phase & Three Phase: (200-240V)
400 V Class Three Phase: (380-480V)
Allowed Variation: +10% to -15%
Rated Frequency
50/60 Hz, Allowed Variation: +5%
Control Method
V/F Control
Frequency Control Range
0.01 to 400 Hz.
Frequency Setting Signal
Main Frequency reference: 0 to +10 Vdc (20 k©),4 to 20 mA (250©), 0 to 20mA (250©).
Speed Control Range
1:20 to 1:40
Braking Torque
Continuous Regen Torque: 20%, 125% with a Braking Resistor Unit (10%ED) for max. 10s.
Overload
Heavy Duty: 150% for 60 Sec.
Normal Duty: 120% for 60 Sec.
Drive Functions
Momentary Power Loss Ride-Thru, Speed Search, Multi-Step Speed (9 steps max), Accel/Decel Time Switch, S-Curve Accel/Decel, 3-Wire Sequence, Cooling Fan ON/OFF, Slip Compensation, Torque Compensation, Frequency Jump, Frequency Reference Upper/Lower Limit, DC Injection Braking (Start and stop), Over excitation Braking, Fault Reset, Parameter Copy.
Protection
Motor Overload, Momentary Over Current, Mains Under voltage, DC Bus Over voltage, Heat sink Overheat, Stall prevention, Over torque, under torque, Input/Output Phase Loss, Output Ground Fault.
Monitors
Reference Frequency, Output Frequency, Output current Output voltage, Output Power, Kwh, Input/Output terminal status, component life monitors for IGBT, Capacitor & Fan, Fault Status & Fault history, communication status.
Input/Output
Digital: 5 nos. Input (24V DC Sink/Source Configuration.1 No. Output (C/O Relay).
Analog: 1 no Input (0-10V or 0/4-20mA) 1 no. Output (0-10V)
Storage/Installation Area
Indoors free from oil mist, dust, harmful gases, liquids & radioactive material.
Ambient Temperature
-10 to +50o C
Storage Temperature
-20 to 60o C
Humidity
95% RH or less with no condensation
Altitude
1000 m or less without derating.
Standard Compliance
RoHS Compliant
Click here for more details.